Check Sweetener Calibration
Possible Cause #
- Product levels don't match calibration figures.
What to Check - Phone #
- Crystalline accumulation in QCD Bag-In-Box connector.
What to Check - Field #
- Obvious signs of product leaking from any of the product line connections.
- Elbows on pump leaking product.
- Product lines restricted due to high viscosity of product or sugar crystalline accumulation.
- Pump runs slow or seizes momentarily during brew cycle.
Action Needed - Phone #
- Clean and reconnect QCD connector.
Action Needed - Field #
- Tighten connections.
- Pump elbows need to be tightened.
- Product lines need to be flushed through the pump with a line flush product e.g. "Easy Clean" weekly.
- Replace sweetener pump.
- Check "Sweetener" calibration and adjust as needed. Ensure the yellow shut-off knob is full vertical on sweetener valve.
- Replace black sweetner flow control valve.
Caution #
Resolution
Did Check Sweetener Calibration resolve the issue?
Yes, resolution code 209.
No, go to next step.