Check Tank Fill Valve
Possible Cause #
- Tank fill solenoid valve
What to Check - Field #
- Loose or burnt wires to coil.
- Coil is shorted (unseen from exterior).
- In/out fittings or valve clogged with water sediment.
Action Needed - Field #
- Use a Volt meter & check across coil terminals. Should read 110-120VAC.
- If there is a correct reading replace the solenoid valve.
- If not, place 1-lead on the gray terminal and the other lead anywhere on the chassis.
- If there is power the coil is bad. Replace solenoid valve.
- If not check continuity on the gray wire to the harness connector with an Ohm meter set to 20k.
- Check the white neutral wire for continuity. If both wires check out replace the main control board.
Caution #
Resolution
Did Check Tank Fill Valve resolve the issue?
Yes, resolution code 205.
No, go to next step.